Advanced Flow Divider Test Bench Solutions for Precision Fuel and Hydraulic Testing A modern flow divider test bench and flow divider test rig are critical for validating accurate flow distribution in complex fuel and hydraulic systems. Designed as a multi-port flow divider tester, the platform supports configurations up to a 16 port flow divider test bench, enabling precise port flow distribution measurement and repeatable flow balancing test system operations. Integrated as a fuel circuit test bench and diesel fuel test rig, the system ensures high-accuracy metering accuracy test bench performance under real operating conditions. The flow divider calibration bench and hydraulic flow divider testing machine allow controlled validation using a back pressure controlled test rig and dual range flow meter test bench for low and high flow regimes. Automation is delivered through a SCADA based test bench and HMI controlled test rig, combined with an automated port switching manifold for efficient testing cycles. As a complete fuel flow measurement system and industrial fuel test bench, it is also available as an ATEX ready fuel test bench for hazardous environments, ensuring safety, compliance, and reliable test results.

Multi-Port Flow Divider Test Bench

About

The Multi-Port Flow Divider Test Bench is a purpose-built, diesel/fuel-circuit validation system designed to precisely characterize and qualify 16-port flow dividers under controlled, repeatable conditions. Flow dividers are widely used in fuel distribution and multi-branch fluid circuits where consistent port-to-port flow is critical for system balance, reliability, and repeatability. This bench eliminates uncertainty by combining a stable recirculating fuel loop with temperature conditioning, multi-stage filtration, adjustable back-pressure loading, and dual-range flow measurement to capture accurate results across low-flow and rated-flow regimes. With automated port-by-port switching, HMI/SCADA-based operation, real-time monitoring, and structured data logging with pass/fail capability, it enables fast distribution mapping, troubleshooting, and traceable reporting—making it ideal for R&D, production inspection, and high-reliability applications where even small distribution errors can lead to performance drift or premature component wear.
No Image

Image Gallery

Technical Details

1) General & Mechanical
Parameter Specification
System type Multi-port flow divider test bench (diesel/fuel circuit)
DUT capacity 16 outlet ports
Measurement method Sequential port routing to Test Header; non-selected ports to Return Header
Operating modes Automatic sequencing + Manual testing
Approx. overall footprint ~2600 mm (L) × ~1200 mm (W)
Approx. overall height ~1800 mm
Mounting / frame Industrial skid-mounted structure with service access for valves, filters, meters
Hose assemblies (typical) ~20 hoses (test + return + utility connections)
2) Test Fluid, Reservoir & Conditioning
Parameter Specification
Working fluid Diesel / fuel media
Reservoir construction Stainless steel tank, drain-friendly geometry
Tank capacity class 800 L class (typical) / 500 L class (alternate configuration)
Temperature conditioning Chiller / heat exchanger loop for controlled fluid temperature
Temperature sensing Transmitter for logging + local indicator (gauge)
Level monitoring Level gauge + level switch (alarm/trip logic capable)
Drain / maintenance Drain points and service access provisions for cleaning and filter changes
3) Pumping & Drive System
Parameter Specification
Pump type Positive displacement pump (gear type class)
Nominal system flow capability ~250 L/min class
Motor type Industrial flameproof / fuel-handling suitable motor
Motor power class ~11 kW (typical build class)
Speed control VFD with smooth ramping and stable RPM holding
Purpose of VFD Repeatable RPM setpoint control, controlled start/stop, reduced hydraulic shock
4) Flow Measurement (Dual-Range)
Parameter Specification
High-range meter purpose Full system / rated-flow operation
High-range flow capability ~1 to 250 L/min class
Low-range meter purpose Low-flow metering and high-resolution distribution checks
Low-range flow capability ~0.03 to 40 L/min class
Measurement principle Positive displacement / gear-type metering suitable for hydrocarbon fuels
Instrument interfacing Industrial analog/pulse interfacing with safe signal conditioning
Per-port flow capability Up to ~14 L/min (3.5 GPM) per port
5) Pressure Control, Loading & Protection
Parameter Specification
Back-pressure control Adjustable back-pressure control valve
Typical test pressure capability Up to ~300 psi class
Pressure measurement Transmitters for logging + local gauges
Circuit protection Relief valves, trips, safe shutdown logic
6) Filtration & Cleanliness Control
Parameter Specification
Suction protection High-flow suction strainer
Fine filtration Multi-stage filtration (typical 10 µm + 6 µm)
Filter serviceability Accessible housings with clog indication provisions
Benefit Protects DUT and metering equipment; improves repeatability
7) Port Switching & Headers
Parameter Specification
Number of switching points 16 (one per port)
Switching logic One port to Test Header; remaining ports to Return Header
Valve type Solenoid / actuated switching valves for fuel service
Header arrangement Dedicated Test Header and Return Header
Key benefit Fast, repeatable testing without hose swapping
8) Controls, HMI/SCADA & Reporting
Parameter Specification
Automation platform HMI + SCADA based control and monitoring
Automatic functions Port sequencing, stabilization/dwell timing, logging, report generation
Manual functions Direct port selection, jog/override, troubleshooting mode
Data logging Time-stamped flow/pressure/temp/RPM data + per-port results
Output format Port-wise tables, deviation %, acceptance verdict, alarms/trips history
Operator interface Live mimic with valve status, trips, key process values
9) Safety & Fuel-Handling Readiness
Parameter Specification
Safety systems E-stop, interlocks, trips, overload protection, controlled shutdown
Electrical philosophy Fuel-handling / hazardous-area oriented component selection
Earthing / bonding Provisioned to minimise static risk
Service safety Drain points, isolation provisions, maintenance-friendly layout
  • Fuel distribution manifolds for multi-outlet diesel and fuel systems
  • Engine and propulsion system flow divider qualification testing
  • Multi-injector and multi-nozzle fuel supply validation rigs
  • Hydraulic flow divider performance and balance testing
  • Lubrication system flow distribution verification
  • Industrial burner and dosing line flow uniformity testing
  • Production and batch testing of multi-port flow dividers
  • R&D and endurance evaluation of flow divider designs
    • Q1: What is a flow divider test bench?
    • A: A flow divider test bench is a dedicated test rig used to measure and verify port-wise flow distribution accuracy of flow dividers under controlled pressure, temperature, and back-pressure conditions. It ensures uniform flow delivery in fuel and hydraulic circuits.

    • Q2: What is the purpose of a 16 port flow divider test bench?
    • A: A 16 port flow divider test bench enables sequential measurement of flow across all divider outlets, creating a detailed port flow distribution map to identify imbalance, leakage, or deviation under real operating conditions.

    • Q3: How does a multi-port flow divider tester measure flow distribution?
    • A: The multi-port flow divider tester routes one outlet at a time to a precision flow meter while recirculating all other ports, allowing accurate port-wise flow measurement without hose swapping or circuit disturbance.

    • Q4: What types of fluids can be tested on this fuel circuit test bench?
    • A: This fuel circuit test bench is designed for diesel and fuel media, using stainless steel reservoirs, fuel-compatible valves, filtration, and ATEX-ready components for safe and repeatable fuel testing.

    • Q5: Why is back-pressure control important in flow divider testing?
    • A: A back-pressure controlled test rig simulates real system loading, revealing flow divider behavior that may only appear under pressure, such as port imbalance, instability, or metering error.

    • Q6: What is the role of dual range flow meters in a flow uniformity test bench?
    • A: Dual range flow meters allow accurate measurement at both very low flows and rated flows, ensuring high-resolution port flow distribution measurement across the entire operating range.

    • Q7: Is this flow divider calibration bench fully automated?
    • A: Yes, the system operates as a SCADA based test bench with HMI control, supporting automated port sequencing, stabilization timing, data logging, deviation analysis, and pass/fail reporting.

    • Q8: Where is a hydraulic flow divider testing machine typically used?
    • A: Hydraulic and fuel flow divider testing machines are used in engine test rigs, injector fuel circuits, propulsion systems, industrial burners, dosing systems, and aerospace or defence fuel qualification labs.

    • Q9: How does an automated port switching manifold improve test accuracy?
    • A: Automated port switching eliminates manual valve handling errors, ensures consistent dwell time per port, and maintains stable fluid conditions, improving repeatability and test confidence.

    • Q10: Is this industrial fuel test bench suitable for hazardous environments?
    • A: Yes, the industrial fuel test bench is engineered with fuel-handling safety logic, earthing and bonding provisions, interlocks, emergency shutdowns, and ATEX-ready component selection for hazardous-area use.

    Key Features

    • Port-by-port certainty: you don’t infer distribution—you measure it.
    • Fast testing: 16 ports can be mapped quickly with sequencing rather than manual replumbing.
    • Realistic operating conditions: back-pressure loading and temperature conditioning reveal real behavior.
    • Wide measurement range: dual-range metering keeps accuracy intact at both low and rated flow.
    • Traceable results: SCADA logging and structured reporting support qualification, audits, and comparisons.
    • Reduced troubleshooting time: abnormal divider signatures become visible immediately in a port map.

    Media Gallery

    Video Gallery

    Download Gallery

    ×

    Enquire Now

    and we will get back to you.

    Details

    Introduction
    Flow dividers are the quiet “truth tellers” of fuel and fluid circuits. Wherever one supply line needs to be split into multiple outlets with predictable, repeatable distribution, a flow divider is the component that decides whether the system runs smoothly or slowly drifts into trouble. They are commonly used in fuel distribution manifolds, engine and propulsion test rigs, multi-injector or multi-nozzle supply circuits, hydraulic and lubrication systems, industrial burners and dosing lines, and other applications where several consumers must receive near-equal flow under changing load and operating conditions.
    
    The criticality is simple: if a divider does not distribute flow accurately, the downstream system may see uneven fueling/dosing, localized heating, performance imbalance, component stress, and repeatability failures that are notoriously hard to diagnose because they can appear only at certain combinations of RPM, pressure, viscosity, and temperature. A divider might look acceptable at one steady condition and still misbehave in real operation—especially at low flow (where internal leakage and friction dominate) or at high load (where differential pressure drives error). That’s why a proper test bench matters: it creates a controlled environment where distribution can be measured port-by-port, under stable and repeatable conditions, and the results can be logged and compared across units, batches, or life-cycle tests.
    
    This system is a purpose-built 16-port flow divider characterization test bench for diesel/fuel circuits. It combines a stable fuel supply loop, dual-range flow measurement, controlled back-pressure loading, sequential outlet switching, and SCADA/HMI-based automation to deliver high-confidence, repeatable distribution data—with a build philosophy suitable for fuel-handling and hazardous-area type environments.
    
    What the system is designed to achieve
    1) Port-wise distribution mapping (the core purpose)
    The bench measures the flow at each outlet one port at a time using an automated switching strategy:
    • The selected port is routed to the Test Header for measurement.
    • All non-selected ports are routed to the Return Header and recirculated back to the tank.
    • The system repeats this sequence for all 16 ports, automatically or manually.
    
    This approach produces a clean and comparable “port map” showing:
    • Flow per port at a given RPM, pressure, and temperature
    • Average flow across ports
    • Deviation of each port from average
    • Repeatability across cycles and across different flow divider units
    
    2) Coverage of real-world operating regimes
    The bench is intended to evaluate performance across the regimes where flow dividers typically show their true behavior:
    • Low-flow metering: where leakage, friction, and internal clearances strongly influence distribution.
    • Rated-flow distribution: where hydraulic loading, back pressure, and stability dominate.
    • Start-up / breakaway behavior (where applicable): capturing transient response and the conditions required to initiate stable operation.
    
    3) Repeatability that is not dependent on operator technique
    Manual testing often suffers from timing differences, inconsistent valve handling, and unstable stabilization time. This bench supports:
    • automatic port sequencing
    • defined dwell/stabilization intervals
    • consistent measurement timing
    • structured data logging and reporting
    
    4) Qualification-style traceable output
    The control system is built to deliver practical outputs:
    • time-stamped logs
    • port-wise tables
    • acceptance verdicts based on defined criteria (deviation limits, stability thresholds, pressure window, etc.)
    • alarm/trip history and operator actions (useful during investigations and audits)
    
    System architecture (how it works)
    A) Fuel supply and conditioning loop (diesel service)
    At the core is a closed-loop diesel circuit engineered for stable test conditions:
    • Diesel reservoir tank in stainless construction, sized to provide thermal mass and stable suction conditions.
    • Drain-friendly bottom geometry to support cleanout and maintenance.
    • Suction protection to prevent pump damage from coarse contaminants.
    • Multi-stage filtration to protect the DUT, switching valves, and meters while ensuring stable measurements.
    • Temperature conditioning using a chiller/heat exchanger so the same divider can be tested at repeatable temperatures (important because viscosity changes with temperature and affects flow distribution).
    • Level monitoring and protection to avoid dry running, aeration, and unsafe operation.
    Practical benefit: this loop prevents “false failures” caused by unstable fluid temperature, air entrainment, or contamination.
    
    B) Pumping and flow stability
    A high-capacity positive displacement pumping package supplies the necessary total flow for a 16-outlet DUT. The drive is VFD-controlled so speed (and therefore flow) can be ramped and stabilized smoothly. Stable inlet conditions are critical—any pulsation or starvation can appear as distribution error and distort results.
    
    C) 16-port switching and header logic (the key enabler)
    Each outlet port is connected through a dedicated switching element so the bench can route:
    • Port N → Test Header → Flow measurement → Return
    • All other ports → Return Header → Tank
    
    This design makes the testing fast, repeatable, and safe compared to manual hose swapping. It also maintains continuous recirculation so the fluid condition remains stable while ports are tested sequentially.
    
    D) Back-pressure module (realistic load simulation)
    A controlled back-pressure valve provides adjustable loading so the divider can be tested at realistic system pressures. This is crucial because distribution can change under load: back-pressure stability is what makes port-to-port comparisons valid.
    
    E) Instrumentation and metrology (wide range without compromise)
    To get meaningful data across operating regimes, the bench employs:
    • Dual-range flow measurement (high-flow and low-flow meters) to maintain accuracy from very low flows up to full system flow.
    • Pressure and temperature transmitters for stable monitoring and SCADA logging.
    • Local gauges for quick operator sanity checks during setup and troubleshooting.
    This gives the bench both high-resolution low-flow metering capability and full-capacity rated-flow capability without sacrificing measurement quality.
    
    F) Control, automation, and operator interface
    The bench is designed for both production-like repeatability and development flexibility:
    • Automatic mode: port sequencing, stabilization, logging, pass/fail.
    • Manual mode: direct operator control for engineering trials, troubleshooting, and calibration checks.
    • HMI interface: setpoints (RPM, pressure), port selection status, live readings (flow/pressure/temp), alarms/trips.
    • SCADA logging: structured test results for traceability and comparisons.
    
    G) Safety and fuel-handling readiness
    Fuel circuits demand a safety-oriented design approach. The bench includes:
    • emergency stop and controlled shutdown
    • overload/overpressure protections
    • interlocks and alarm logic
    • appropriate component selection for fuel service and hazardous-area type environments
    • good industrial practices: earthing/bonding provisions, protected routing, and robust enclosure selection
    
    Typical test workflows (how a test run looks)
    Workflow 1: Low-flow distribution test
    1. Stabilize tank level and temperature.
    2. Set low RPM and target back pressure (if needed).
    3. Run automatic port sequencing with a defined dwell per port.
    4. Record port-wise flows, compute deviations, and assess repeatability by running multiple cycles.
    What it catches: leakage imbalance, internal friction issues, sensitivity to viscosity, early-life defects.
    
    Workflow 2: Rated-flow distribution test (low pressure + high pressure)
    1. Ramp to rated RPM under controlled conditions.
    2. Run a complete port map at low pressure.
    3. Increase back pressure to high condition and repeat.
    4. Compare deviation signatures across both conditions.
    What it proves: performance under realistic load and stability across pressure conditions.
    
    Workflow 3: Start-up / breakaway behavior (where applicable)
    1. Start from a controlled initial condition.
    2. Observe transient response and stabilization behavior.
    3. Identify abnormal signatures indicating sticking, high friction, or internal wear.
    
    Technical Specifications (Detailed)
    Where parameters are application-dependent, the bench is configurable within its hardware capability. The following table describes a detailed capability set aligned to this system’s build class.
    1) General & Mechanical
    
    Parameter Specification
    System type Multi-port flow divider test bench (diesel/fuel circuit)
    DUT capacity 16 outlet ports
    Measurement method Sequential port routing to Test Header; non-selected ports to Return Header
    Operating modes Automatic sequencing + Manual testing
    Approx. overall footprint ~2600 mm (L) × ~1200 mm (W)
    Approx. overall height ~1800 mm
    Mounting / frame Industrial skid-mounted structure with service access for valves, filters, meters
    Hose assemblies (typical) ~20 hoses (test + return + utility connections)
    2) Test Fluid, Reservoir & Conditioning
    Parameter Specification
    Working fluid Diesel / fuel media
    Reservoir construction Stainless steel tank, drain-friendly geometry
    Tank capacity class 800 L class (typical) / 500 L class (alternate configuration)
    Temperature conditioning Chiller / heat exchanger loop for controlled fluid temperature
    Temperature sensing Transmitter for logging + local indicator (gauge)
    Level monitoring Level gauge + level switch (alarm/trip logic capable)
    Drain / maintenance Drain points and service access provisions for cleaning and filter changes
    3) Pumping & Drive System
    Parameter Specification
    Pump type Positive displacement pump (gear type class)
    Nominal system flow capability ~250 L/min class
    Motor type Industrial flameproof / fuel-handling suitable motor
    Motor power class ~11 kW (typical build class)
    Speed control VFD with smooth ramping and stable RPM holding
    Purpose of VFD Repeatable RPM setpoint control, controlled start/stop, reduced hydraulic shock
    4) Flow Measurement (Dual-Range)
    Parameter Specification
    High-range meter purpose Full system / rated-flow operation
    High-range flow capability ~1 to 250 L/min class
    Low-range meter purpose Low-flow metering and high-resolution distribution checks
    Low-range flow capability ~0.03 to 40 L/min class
    Measurement principle Positive displacement / gear-type metering suitable for hydrocarbon fuels
    Instrument interfacing Industrial analog/pulse interfacing with safe signal conditioning
    Per-port flow capability Up to ~14 L/min (3.5 GPM) per port
    5) Pressure Control, Loading & Protection
    Parameter Specification
    Back-pressure control Adjustable back-pressure control valve
    Typical test pressure capability Up to ~300 psi class
    Pressure measurement Transmitters for logging + local gauges
    Circuit protection Relief valves, trips, safe shutdown logic
    6) Filtration & Cleanliness Control
    Parameter Specification
    Suction protection High-flow suction strainer
    Fine filtration Multi-stage filtration (typical 10 µm + 6 µm)
    Filter serviceability Accessible housings with clog indication provisions
    Benefit Protects DUT and metering equipment; improves repeatability
    7) Port Switching & Headers
    Parameter Specification
    Number of switching points 16 (one per port)
    Switching logic One port to Test Header; remaining ports to Return Header
    Valve type Solenoid / actuated switching valves for fuel service
    Header arrangement Dedicated Test Header and Return Header
    Key benefit Fast, repeatable testing without hose swapping
    8) Controls, HMI/SCADA & Reporting
    Parameter Specification
    Automation platform HMI + SCADA based control and monitoring
    Automatic functions Port sequencing, stabilization/dwell timing, logging, report generation
    Manual functions Direct port selection, jog/override, troubleshooting mode
    Data logging Time-stamped flow/pressure/temp/RPM data + per-port results
    Output format Port-wise tables, deviation %, acceptance verdict, alarms/trips history
    Operator interface Live mimic with valve status, trips, key process values
    9) Safety & Fuel-Handling Readiness
    Parameter Specification
    Safety systems E-stop, interlocks, trips, overload protection, controlled shutdown
    Electrical philosophy Fuel-handling / hazardous-area oriented component selection
    Earthing / bonding Provisioned to minimise static risk
    Service safety Drain points, isolation provisions, maintenance-friendly layout
    Key advantages (why this bench is the right approach) • Port-by-port certainty: you don’t infer distribution—you measure it. • Fast testing: 16 ports can be mapped quickly with sequencing rather than manual replumbing. • Realistic operating conditions: back-pressure loading and temperature conditioning reveal real behavior. • Wide measurement range: dual-range metering keeps accuracy intact at both low and rated flow. • Traceable results: SCADA logging and structured reporting support qualification, audits, and comparisons. • Reduced troubleshooting time: abnormal divider signatures become visible immediately in a port map. Common options (if you want to make it even more powerful) • Recipe-based testing (predefined RPM/pressure/temperature profiles) • Auto-stability detection (log only after values settle within tolerance) • Statistical reporting (mean, standard deviation, repeatability index per port) • Serial number / barcode tracking for batch testing • Additional temperature points (tank + inlet + outlet) for tighter viscosity control • Higher pressure variant or additional loading module (if future DUTs require it) • Remote monitoring and automatic report export

    Trending Products

    Share This Page